Metadata-Version: 2.1
Name: wearablehrv
Version: 0.2.0
Summary: Wearablehrv: A Python package for the validation of heart rate and heart rate variability in wearables.
Home-page: https://github.com/AminSinichi/wearable-hrv
Author: Amin Sinichi
Author-email: aminsinichi@gmail.com
License: UNKNOWN
Platform: UNKNOWN
Classifier: Programming Language :: Python :: 3
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Requires-Python: >=3.6
Description-Content-Type: text/markdown
Requires-Dist: pandas
Requires-Dist: numpy
Requires-Dist: plotly
Requires-Dist: pooch
Requires-Dist: matplotlib
Requires-Dist: ipywidgets
Requires-Dist: IPython
Requires-Dist: hrv-analysis
Requires-Dist: avro-python3
Requires-Dist: pingouin
Requires-Dist: seaborn
Requires-Dist: statsmodels
Requires-Dist: scipy
Requires-Dist: astropy <6.0

![cover](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/cover.png)

[![License: MIT](https://img.shields.io/badge/License-MIT-yellow.svg)](https://opensource.org/licenses/MIT)
[![Current version at PyPI](https://img.shields.io/pypi/v/wearablehrv.svg)](https://pypi.org/project/wearablehrv/)
![Supported Python Versions](https://img.shields.io/pypi/pyversions/wearablehrv.svg)
![Last Commit](https://img.shields.io/github/last-commit/Aminsinichi/wearable-hrv)
[![Twitter Follow](https://img.shields.io/twitter/follow/AminSinichi.svg?style=social)](https://twitter.com/AminSinichi)
[![Binder](https://mybinder.org/badge_logo.svg)](https://mybinder.org/v2/gh/Aminsinichi/wearable-hrv/master?labpath=docs%2Fexamples%2F)

`wearablehrv` is a Python package that comes in handy if you want to validate wearables and establish their accuracy in terms of heart rate (HR) and heart rate variability (HRV). `wearablehrv` is a complete and comprehensive pipeline that helps you go from your recorded raw data through all the necessary pre-processing steps, data analysis, and many visualization tools with graphical user interfaces.

# Documentation

For the complete documentation of the API and modules, visit:

[![Documentation Status](https://readthedocs.org/projects/wearable-hrv/badge/?version=latest)](https://wearable-hrv.readthedocs.io/en/latest/?badge=latest)

**Examples**

*Getting Started*

- [Installation guide for wearablehrv](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/getting_started/installation.ipynb)
- [An overview of main functionalities](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/getting_started/overview.ipynb)

*Individual Pipeline*

- [How to prepare your data for the individual pipeline](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/individual_pipeline/1.individual_data_preparation.ipynb)
- [Preprocess your data](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/individual_pipeline/2.individual_data_preprocessing.ipynb)
- [Analyze your data](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/individual_pipeline/3.individual_data_analysis.ipynb)
- [Plot your data](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/individual_pipeline/4.individual_data_plotting.ipynb)
- [Learn more about the compatibility of wearablehrv with other platforms (Labfront, VU-AMS, Empatica)](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/individual_pipeline/individual_compatibility.ipynb)

*Group Pipeline*

- [How to prepare your data for the group pipeline](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/group_pipeline/1.group_data_preparation.ipynb)
- [Determine the signal quality of your wearables](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/group_pipeline/2.group_signal_quality.ipynb)
- [Perform four major statistical analyses to determine validity](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/group_pipeline/3.group_data_analysis.ipynb)
- [Descriptive plots for your group data](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/examples/group_pipeline/4.group_data_plotting.ipynb)

You can also explore the example notebooks directly in your browser without installing any packages by using Binder. Simply click the badge below to get started:

[![Binder](https://mybinder.org/badge_logo.svg)](https://mybinder.org/v2/gh/Aminsinichi/wearable-hrv/master?labpath=docs%2Fexamples%2F)

# User Installation

The package can be easily installed using `pip`:

    pip install wearablehrv

The repository can be cloned:

    git clone https://github.com/Aminsinichi/wearable-hrv.git

# Development

`wearablehrv` was developed by Amin Sinichi <https://orcid.org/0009-0008-2491-1542>, during his PhD at Vrije Universiteit Amsterdam in Psychophysiology and Neuropsychology.  

**Contributors**

- [Dr. Martin Gevonden](https://orcid.org/0000-0001-7867-1443)
- [Prof dr. Lydia Krabbendam](https://orcid.org/0000-0003-4074-5149)

# Overview

The package is divided into two broad ranges of functionalities:

- **Individual Pipeline**: You use it for a single participant to process your raw data.
- **Group Pipeline**: You use it when you have multiple participants, and you have processed them through the Individual Pipeline.

Below, we offer a quick overview of the main functionalities.

## Data Collection

When one wants to establish the validity of a wearable, let's say a smartwatch, that records heart rate and heart rate variability, they should use a "ground truth" device. This is usually a gold-standard electrocardiography (ECG) that measures HR and HRV accurately.

**Note**: We call this gold-standard a "criterion" device in our pipeline.

Then, a participant wears this ECG, together with the smartwatch, and starts recording data simultaneously. It is beneficial if we test the subject in various conditions, so we get a better sense of how well the device works.

Usually, validating multiple devices at once is a cumbersome task, requiring a lot of data preparation, processing, different alignments, etc. **A powerful feature in `wearablehrv` is that it does not matter how many devices in how many conditions you want to test a participant!** You just record your data, and the pipeline walks you through this data to the final decision on whether a device is accurate compared to the ground truth or not.

This is how your experiment may look like: a participant wearing a few wearables named Kyto, Heartmath, Empatica, Rhythm, together with a gold-standard ECG (VU-AMS), with electrodes on the chest, and will perform different tasks in different conditions (e.g., sitting for 5 minutes, standing up for 3 minutes, walking for 3 minutes, and biking for 3 minutes, while having all the devices on):

![Sensor Placement](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/Sensor%20Placement.png?raw=true)

## 1. Individual Pipeline

### 1.1 Prepare Data

It is easy to read your data and experimental events with the pipeline from all your devices in one go.

```python
# Importing Module
import wearablehrv

# downloading some example data
path = wearablehrv.data.download_data_and_get_path()
# Define the participant ID 
pp = "test" 
# Define your experimental conditions, for instance, sitting, standing, walking, and biking
conditions = ['sitting', 'standing', 'walking', 'biking'] 

# Define the devices you want to validate against the criterion. 
devices = ["kyto", "heartmath", "rhythm", "empatica", "vu"] 

# Redefine the name of the criterion device
criterion = "vu" 

# Read data, experimental events, and segment the continuous data into smaller chunks
data = wearablehrv.individual.import_data (path, pp, devices)
events = wearablehrv.individual.define_events (path, pp, conditions, already_saved= True, save_as_csv= False)
data_chopped = wearablehrv.individual.chop_data (data, conditions, events, devices)
```

### 1.2 Preprocess Data

You have various methods to properly preprocess your raw data.

**Correct the Lag, Trim Data**

With a user-friendly GUI, correct the lag between devices, align data by cropping the beginning and the end of each of your devices, and have full control over each device and condition.

```python
wearablehrv.individual.visual_inspection (data_chopped, devices, conditions,criterion)
```

![visual_inspection](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/visual_inspection.PNG)

**Detect Outliers and Ectopic Beats**

Easily perform different types of detection methods for each device and in each condition. This is an important advantage that allows you to easily run this within a condition, for a specific device, to make the preprocessing independent.

```python
data_pp, data_chopped = wearablehrv.individual.pre_processing (data_chopped, devices, conditions, method="karlsson", custom_removing_rule = 0.25, low_rri=300, high_rri=2000)
```

**Diagnostic Plots**

Check how well you performed the preprocessing by comparing the detected outliers in the criterion and your selected device.

```python
wearablehrv.individual.ibi_comparison_plot(data_chopped, data_pp, devices, conditions, criterion, width=20, height=10)
```

![comparison_plot](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/comparison_plot.PNG)

### 1.3 Analyze and Plot

Easily calculate all relevant outcome variables (e.g., RMSSD, mean HR, frequency domain measures) in all your devices and conditions, and use various plotting options.

```python
time_domain_features, frequency_domain_features = wearablehrv.individual.data_analysis(data_pp, devices, conditions)
wearablehrv.individual.bar_plot(time_domain_features, frequency_domain_features, devices, conditions, width=20, height=25, bar_width = 0.15)
```

![bar_plot](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/bar_plot.PNG)

## 2. Group Pipeline

### 2.1 Prepare Data

Easily load all processed data that you have put through the Individual Pipeline.

```python
wearablehrv.data.clear_wearablehrv_cache() 
path = wearablehrv.data.download_data_and_get_path(["P01.csv", "P02.csv", "P03.csv", "P04.csv", "P05.csv", "P06.csv", "P07.csv", "P08.csv", "P09.csv", "P10.csv"])
conditions = ['sitting', 'standing', 'walking', 'biking'] 
devices = ["kyto", "heartmath", "rhythm", "empatica", "vu"] 
criterion = "vu" 
features = ["rmssd", 'mean_hr', 'nibi_after_cropping', 'artefact'] 
data, file_names = wearablehrv.group.import_data(path, conditions, devices, features) # Select the features you are interested in
data = wearablehrv.group.nan_handling(data, devices, features, conditions) 
```

### 2.2 Signal Quality

A powerful tool to assess and report signal quality in all your wearables, in all conditions. You just need to define a few thresholds.

```python
data, features, summary_df, quality_df = wearablehrv.group.signal_quality(data, path, conditions, devices, features, criterion, file_names, ibi_threshold = 0.30, artefact_threshold = 0.30)
wearablehrv.group.signal_quality_plot2(summary_df, condition_selection=False, condition=None)
```

![signal_quality](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/signal_quality.PNG)

### 2.3 Statistical Analysis

Perform four of the most common statistical methods for validation, and create plots, again, for all your devices, in all conditions, just by running a few functions.

**Mean Absolute Percentage Error**

```python
mape_data = wearablehrv.group.mape_analysis(data, criterion, devices, conditions, features)
wearablehrv.group.mape_plot(mape_data, features, conditions, devices)
```

![mape](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/mape.PNG)

**Regression Analysis**

```python
regression_data = wearablehrv.group.regression_analysis(data, criterion, conditions, devices, features, path)
wearablehrv.group.regression_plot(regression_data, data, criterion, conditions, devices, features, marker_color='red', width=10, height_per_condition=4)
```

![regression](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/regression.PNG)

**Intraclass Correlation Coefficient**

```python
icc_data = wearablehrv.group.icc_analysis(data, criterion, devices, conditions, features, path, save_as_csv=False)
wearablehrv.group.icc_plot(icc_data, conditions, devices, features)
```

![icc](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/icc.PNG)

**Bland-Altman Analysis**

```python
blandaltman_data = wearablehrv.group.blandaltman_analysis(data, criterion, devices, conditions, features, path, save_as_csv=False)
wearablehrv.group.blandaltman_plot(data, criterion, conditions, devices, features)
```

![bland_altman](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/bland_altman.PNG)

### 2.4 Descriptive Plots

There are many options for you to meaningfully plot your group data and make an informed decision on the accuracy of your devices.

```python
wearablehrv.group.violin_plot (data, conditions, features, devices)
```

![violin plot](https://github.com/Aminsinichi/wearable-hrv/blob/master/docs/img/violin%20plot.png)

# Questions

For any questions regarding the package, please contact:

- <aminsinichi@gmail.com>
- <m.sinichi@vu.nl>


