Metadata-Version: 2.4
Name: cristma
Version: 0.1.0b14
Summary: Physics-first crystallography, crystal chemistry, and periodic structure analysis
License-Expression: BSD-3-Clause
Project-URL: Repository, https://github.com/ABKuznetsov/CrIStMa
Project-URL: Issues, https://github.com/ABKuznetsov/CrIStMa/issues
Classifier: Development Status :: 4 - Beta
Classifier: Intended Audience :: Science/Research
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.11
Classifier: Topic :: Scientific/Engineering :: Chemistry
Classifier: Topic :: Scientific/Engineering :: Physics
Requires-Python: >=3.11
Description-Content-Type: text/markdown
License-File: LICENSE
License-File: THIRD_PARTY_NOTICES.md
Requires-Dist: numpy>=1.26
Provides-Extra: reference-build
Requires-Dist: gemmi==0.7.5; extra == "reference-build"
Requires-Dist: spglib==2.7.0; extra == "reference-build"
Requires-Dist: xraylib==4.3.0; extra == "reference-build"
Dynamic: license-file

# CrIStMa

**Crystallographic Infrastructure for Structures and Materials.**

A compact, physics-first Python library for crystallography, crystal chemistry,
and periodic structure analysis.

[![Python](https://img.shields.io/badge/Python-3.11%2B-1479b8)](https://www.python.org/)
![Platform](https://img.shields.io/badge/Platform-Windows%20%7C%20macOS%20%7C%20Linux-777777)
[![License](https://img.shields.io/badge/License-BSD--3--Clause-55a630)](https://github.com/ABKuznetsov/CrIStMa/blob/main/LICENSE)
[![Status](https://img.shields.io/badge/Status-Beta-e6a700)](https://pypi.org/project/cristma/)

## Overview

CrIStMa provides a common scientific foundation for programs that work with
crystal and molecular structures. It reads widely used structural formats,
maps them into one canonical model, and offers independent tools for symmetry,
geometry, crystal chemistry, and periodic topology.

The project exists because scientific logic is often coupled to a particular
file parser, graphical application, or large external framework. That makes
calculations difficult to reuse, compare, and audit. CrIStMa keeps these layers
separate: formats end at the I/O boundary, scientific operations receive
explicit inputs, and results retain diagnostics and provenance.

CrIStMa is not an end-user application and does not prescribe a workflow. It
is a reusable scientific library for scripts, notebooks, research software,
desktop applications, and automated data-processing systems.

## What it can do

- read CIF, SHELX RES/INS, VASP, PDB, XYZ, and extXYZ structures through one
  content-aware API;
- preserve source documents where supported or write a normalized structure;
- represent periodic crystals and non-periodic molecules as distinct physical
  models;
- expand crystallographic sites using exact symmetry operations;
- use a bundled catalog of all 530 Hall settings and their Wyckoff positions;
- build symmetry orbits and assign Wyckoff positions;
- generate reciprocal reflections down to a physical `d_min`, including exact
  systematic absences, crystallographic multiplicity, and Friedel relations;
- calculate neutral-atom X-ray structure factors `F`, `|F|`, and `|F|²` from
  independent crystallographic sites and an explicit Hall setting;
- calculate intrinsic powder-line angles and multiplicity-weighted strengths
  for explicit single- or multi-component radiation, including selectable Cr,
  Fe, Co, Cu, Mo, and Ag Kα1/Kα2 sources and monochromatic synchrotron X-rays;
- apply explicit Bragg–Brentano Lorentz and X-ray polarization corrections;
- calculate finite and periodic neighbour graphs and coordination
  environments;
- analyze composition, oxidation-state evidence, coordination shells, and
  coordination polyhedra;
- return an explicit crystal-chemistry resolution status and stable
  symmetry-equivalent contact orbits for downstream applications;
- assemble structural units and classify periodic blocks as finite units,
  chains, layers, or frameworks;
- find translation-aware finite rings in periodic structural
  representations;
- resolve intramolecular bond orbits and classify connected components as
  discrete molecules, chains, layers, or frameworks by exact periodic rank;
- report recoverable problems as structured diagnostics instead of hiding
  assumptions or silently changing the input.

## Scientific model

All supported formats converge on the same native structures:

```text
CIF / RES / INS / POSCAR / XDATCAR / OUTCAR / vasprun.xml / PDB / XYZ / extXYZ
                                |
                                v
             CrystalStructure | MolecularStructure
                                |
                                v
 symmetry / geometry / chemistry / periodic topology / reciprocal reflections
```

The canonical structure is the source of truth for calculations. Parsed
documents remain available for source preservation and provenance, but
file-specific details do not control downstream scientific semantics.

Calculated objects are immutable results rather than hidden application state.
The caller decides calculation order, caching, storage, presentation, and user
interaction.

## Installation

CrIStMa requires Python 3.11 or newer.

Install the public beta from PyPI:

```bash
python -m pip install --pre cristma
```

To install the current source checkout:

```bash
git clone https://github.com/ABKuznetsov/CrIStMa.git
cd CrIStMa
python -m pip install -e .
```

NumPy is the only runtime dependency. Optional development and reference-data
dependencies are kept outside the scientific runtime.

## Quick start

```python
import cristma
from cristma.geometry import CoordinationAnalyzer, NeighborFinder
from cristma.symmetry import expand_structure

result = cristma.read("sample.cif")

for diagnostic in result.diagnostics:
    print(diagnostic.severity.value, diagnostic.code, diagnostic.message)

if not result.ok or not result.structures:
    raise RuntimeError("The structure could not be read")

crystal = result.structures.primary or result.structures[0]
view = expand_structure(crystal)
neighbors = NeighborFinder(cutoff=3.0).find(view)
coordination = CoordinationAnalyzer().analyze(view, neighbors)

print(crystal.cell.volume)
print(len(view.atoms), len(neighbors.edges))
print(len(coordination.environments))
```

The same entry point reads other supported formats:

```python
structure = cristma.read("POSCAR").structures[0]
trajectory = cristma.read("XDATCAR").structures
model = cristma.read("molecule.pdb").structures[0]
```

## Native structure I/O

| Format | Reading | Writing | Notes |
| --- | --- | --- | --- |
| CIF 1.1 | Yes | Preserve and canonical | Source order, comments, unknown tags, and numeric text can be retained |
| SHELX RES/INS | Yes | Preserve and canonical | Canonical output requires an explicit wavelength |
| VASP POSCAR/CONTCAR | Yes | — | Selective Dynamics and reported velocities are retained |
| VASP XDATCAR | Yes | — | Frames are indexed and loaded lazily |
| VASP OUTCAR | Structural frames | — | Per-atom forces and units are retained |
| `vasprun.xml` | Structural frames | — | Trajectory-oriented structural parsing |
| PDB | Yes | — | Crystal and molecular coordinate models |
| XYZ/extXYZ | Yes | — | Typed properties and lazy trajectories |

CrIStMa implements these readers natively. Gemmi, pymatgen, PyXtal, CrysPy,
GSAS-II, SHELX, and graphical frameworks are not required at runtime.

Recoverable source-property problems do not discard otherwise usable
coordinates. CIF occupancies outside their physical `[0, 1]` interval are
retained in their reported raw form, normalized to the nearest bound for
calculation, and reported by a warning diagnostic. Overfilled coincident mixed
positions are normalized proportionally. Fractional coordinates are periodic
and are therefore not clamped to `[0, 1]`; reported ADP values likewise keep
their own physical convention and are not treated as occupancies. Atom-site
loops are mapped by tag name rather than column position. A non-standard
trailing `t` attached to a fractional symmetry translation (for example
`z+1/2t`) is removed only after strict parsing fails, and every repaired
operation produces a warning with the exact recovered expression.

Cell-metric compatibility and special-position matching respect the precision
reported by each CIF number; exact symmetry operations themselves remain
exact. If an atom loop redundantly lists symmetry-generated copies of the same
site, CrIStMa conservatively collapses only chemically and structurally
compatible rows and records every source alias in provenance. Conflicting
species, occupancies, disorder, displacement parameters, or site metadata are
kept separate and reported diagnostically. Unusable polyhedron hull geometry
similarly produces an `INCOMPLETE` calculated polyhedron with its valid
vertices retained instead of aborting the structure analysis.

## Reflection generation

The first diffraction layer generates complete reciprocal-space reflection
orbits without requiring an atomic structure. It accepts an explicit unit cell,
one unambiguous catalog `SpaceGroupSetting`, and a resolution limit:

```python
from cristma.crystallography import SpaceGroupCatalog
from cristma.diffraction import ReflectionGenerator

setting = SpaceGroupCatalog.default().by_setting(523)
reflection_set = ReflectionGenerator().generate(
    cell=crystal.cell,
    space_group=setting,
    d_min=0.8,
)

allowed = reflection_set.allowed
absent = reflection_set.systematically_absent
```

Systematic absences are derived from exact symmetry-operation phases, not from
group-name heuristics or expected-reflection tables.

## Orbit-first crystal chemistry

Direct-space crystal chemistry starts from independent sites and an explicit,
validated symmetry context. Symmetry orbits are the scientific results;
expanded contact instances are created only for a consumer-requested region.

```python
from cristma.chemistry import ChemistryAnalyzer, Composition
from cristma.crystallography import SymmetryContext
from cristma.crystal_chemistry import (
    ContactAnalyzer,
    PolyhedronOrbitBuilder,
    ReferenceCell,
    ShellResolutionPolicy,
)

context = SymmetryContext.from_definition(crystal.space_group, crystal.cell)
chemistry = ChemistryAnalyzer().analyze(Composition.from_structure(crystal))
result = ContactAnalyzer(
    ShellResolutionPolicy(1.60, 0.01, 0.08, 0.01, 2.0)
).analyze(crystal, context, chemistry.grammar)
polyhedra = PolyhedronOrbitBuilder().build(result)

# Outward-only compatibility/materialization boundary:
reference_cell_contacts = result.materialize_contacts(ReferenceCell())
assert result.contacts == reference_cell_contacts
```

Molecular connectivity is a separate calculation over the same resolved
contact orbits. Its bond boundary is explicit and phase-independent:

```python
from cristma.crystal_chemistry import (
    MolecularAnalysisPolicy,
    MolecularAnalyzer,
    MolecularRingSearchPolicy,
)

molecular = MolecularAnalyzer(
    MolecularAnalysisPolicy(maximum_bond_rho=1.25),
    MolecularRingSearchPolicy(maximum_ring_size=12),
).analyze(result)
```

The result contains immutable molecular bond and component orbits. Component
periodicity is derived from exact affine-labelled graph closures: rank zero is
a discrete molecule, ranks one and two are a chain and layer, and rank three
is a framework. Packing contacts are not promoted to molecular bonds merely
because they occurred inside the broader contact-search buffer.

For proven discrete molecular components, `ring_orbits` reports bounded,
symmetry-unique chordless shortest-return graph cycles. Ring atoms retain
exact periodic relations, while centroid, normal and planarity RMS are derived
geometric descriptors. A reached search bound marks the result incomplete
without discarding rings already proved; degenerate geometry likewise keeps
the graph ring and reports the unavailable descriptor diagnostically. This
layer makes no aromaticity, pi-system or smallest-ring-set claim.

Pi-system screening is a separate optional calculation, so molecular
connectivity and ring identity never depend on this interpretation:

```python
from cristma.crystal_chemistry import PiSystemAnalyzer, PiSystemPolicy

pi_systems = PiSystemAnalyzer(
    PiSystemPolicy(maximum_planarity_rms_angstrom=0.12)
).analyze(result, molecular)
```

Each retained candidate preserves the complete component and occupancy
evidence at every ring position. Mixed qualifying and non-qualifying
components remain explicit and make the candidate ambiguous. The result means
only that a molecular ring passes the declared planarity and composition
screen; it does not assign aromaticity, bond order, electron delocalization,
or interaction energy.

Pairs of retained pi-system candidates can be screened independently for
stacking geometry:

```python
from cristma.crystal_chemistry import PiStackingAnalyzer, PiStackingPolicy

pi_stacking = PiStackingAnalyzer(
    PiStackingPolicy(
        minimum_centroid_distance_angstrom=3.2,
        maximum_centroid_distance_angstrom=4.2,
        maximum_plane_angle_deg=20.0,
        maximum_lateral_offset_angstrom=2.0,
    )
).analyze(result, molecular, pi_systems)
```

This search operates directly on symmetry orbits with an exact periodic
relation and a cutoff-complete lattice buffer. It reports geometry-qualified
pi-stacking candidates, not interaction energies or a packing hierarchy.

Explicit C-H and C-D molecular-bond orbits can be screened independently
against those same pi-system candidates:

```python
from cristma.crystal_chemistry import CHPiAnalyzer, CHPiPolicy

ch_pi = CHPiAnalyzer(
    CHPiPolicy(
        maximum_hydrogen_centroid_distance_angstrom=3.0,
        minimum_carbon_hydrogen_centroid_angle_deg=120.0,
    )
).analyze(result, molecular, pi_systems)
```

The reported angle is C-H-centroid at hydrogen. The directed periodic
relation and source bond orbit remain explicit; missing hydrogens are never
generated, and a molecule's own pi system is excluded by exact molecular-orbit
identity rather than a coordinate heuristic.

The completed interaction results can then be assembled into one molecular
packing quotient graph:

```python
from cristma.crystal_chemistry import PackingAnalyzer

packing = PackingAnalyzer().analyze(
    intermolecular,
    pi_stacking,
    ch_pi,
)
```

Graph nodes reference discrete molecule orbits. Exact relation-labelled edges
merge van der Waals, hydrogen-bond, pi-stacking, and C-H...pi evidence that
describes the same molecular pair relation. Connected-component rank is an
exact periodic-connectivity result only; CrIStMa does not assign interaction
energies, motif names, a preferred packing hierarchy, or presentation state.

Explicit instances are created only at the outward materialization boundary:

```python
from cristma.crystal_chemistry import (
    PackingInteractionKind,
    PackingMaterializer,
    ReferenceCell,
)

packing_view = PackingMaterializer().materialize(
    packing,
    ReferenceCell(),
    # Optional scientific-evidence filter:
    interaction_kinds=(PackingInteractionKind.PI_STACKING,),
)
```

The result contains materialized molecules and connections with stable source
orbit IDs, exact periodic relations, reference-cell atom IDs, and cell
translations. Connections across a cell boundary retain their neighbouring
molecule endpoint, while canonical ownership prevents duplicate edges.

Intermolecular contacts reuse that same bounded pair table; they never launch
a second neighbour search:

```python
from cristma.crystal_chemistry import (
    IntermolecularContactAnalyzer,
    IntermolecularContactPolicy,
)

intermolecular_policy = IntermolecularContactPolicy()
result = ContactAnalyzer(
    ShellResolutionPolicy(1.60, 0.01, 0.08, 0.01, 2.0),
    minimum_pair_cutoff=intermolecular_policy.maximum_distance_angstrom,
).analyze(crystal, context, chemistry.grammar)
molecular = MolecularAnalyzer(
    MolecularAnalysisPolicy(maximum_bond_rho=1.25)
).analyze(result)
intermolecular = IntermolecularContactAnalyzer(
    intermolecular_policy
).analyze(result, molecular)
```

This first slice reports symmetry-unique geometric contact orbits, exact
molecule-to-molecule periodic relations, van der Waals distance evidence, and
geometry-qualified hydrogen-bond candidates for explicit H or D atoms. It does
not infer missing hydrogens. Named packing assemblies, voids, interaction
energies, Hirshfeld surfaces, and reticular topology are deferred.
Metal-organic fragments are not presented as ordinary molecular packing.

`ContactAnalysisResult` exposes pair orbits, chemically resolved contact
orbits, oriented incidence orbits, coordination-shell alternatives, explicit
status, diagnostics, configuration and provenance. Polyhedron orbits retain
oriented periodic atom references, coordination number, occupancy-weighted
ligand composition, convex-hull faces, bond-length statistics, the Baur
distortion index, edge-angle population dispersion, volume, geometric
centroid and centre offset.

The canonical face signature represents the complete vertex-edge-face
incidence graph. Shape descriptors are not guessed for open or degenerate
shells: unavailable values remain `None` and the reason is diagnostic. CrIStMa
does not triangulate display meshes or define colours, visibility, selection,
tables or motif-comparison policy; those are responsibilities of consuming
applications.

## Structural hierarchy

The hierarchy remains on the same finite symmetry quotient graph. No stage
below consumes materialized contacts or an expanded atomic view:

```python
units = StructuralUnitBuilder().build(result, polyhedra)
graph = StructuralGraphBuilder().build(result, polyhedra)
representation = StructuralRepresentationBuilder(selection_policy).build(graph)
connectivity = PeriodicConnectivityAnalyzer().analyze(representation)
blocks = StructuralBlockFinder().find(representation, connectivity)
rings = RingFinder().find(representation, blocks)
```

The results expose stable unit, connection, block and ring orbit identities.
Periodic rank comes from exact affine cycle translations, not geometric
heuristics. `StructuralUnitGeometry` records only calculated points, linear
groups, planar polygons, or closed polyhedra. Rendering meshes, colours,
visibility, tree grouping, matching and interactive comparison remain outside
CrIStMa.

## X-ray structure factors

The first scattering layer calculates forward neutral-atom X-ray amplitudes
from a `CrystalStructure` and its generated `ReflectionSet`:

```python
from cristma.crystallography import (
    SpaceGroupCatalog,
    SpaceGroupSettingResolutionStatus,
    resolve_space_group_setting,
)
from cristma.diffraction import StructureFactorCalculator, XRayScatteringContext

resolution = resolve_space_group_setting(
    crystal.space_group,
    SpaceGroupCatalog.default(),
)
if resolution.status is not SpaceGroupSettingResolutionStatus.RESOLVED:
    raise ValueError("the structure has no unique catalog setting")
setting = resolution.setting

factors = StructureFactorCalculator().calculate(
    structure=crystal,
    space_group=setting,
    reflections=reflection_set,
    context=XRayScatteringContext.default(),
)
```

Setting resolution compares the complete exact operation set in the reported
fractional basis. It returns `AMBIGUOUS` or `UNRESOLVED` instead of selecting a
setting from a Hermann–Mauguin symbol or space-group number alone. The
diffraction calculators themselves still accept only a uniquely resolved
`SpaceGroupSetting`.

The calculator expands independent sites with the supplied exact symmetry,
deduplicates special positions, applies occupancies and isotropic displacement
parameters, and returns `F`, `|F|`, and `|F|²` without multiplying by reflection
multiplicity. The bundled `f0(s)` table covers neutral atoms H through Cf and
does not require xraylib at runtime. Anisotropic displacement parameters and
anomalous scattering are not evaluated directly in v1. When a source reports
`U_aniso` together with `U_iso_or_equiv`, the calculator uses the reported
equivalent isotropic value and returns an explicit warning. Without that value,
the position is calculated with `T=1` and the result carries an error diagnostic
plus the affected site IDs instead of aborting the complete calculation.

This is forward crystallographic physics only. Experimental peak matching,
similarity measures, R-factors, powder corrections, and phase identification
belong to consuming applications or later independent layers.

## Powder diffraction lines

The next layer groups Friedel mates and calculates a separate Bragg angle for
every component of an explicit radiation spectrum:

```python
from cristma.diffraction import (
    BraggBrentanoGeometry,
    PowderCorrectionCalculator,
    PowderLineCalculator,
    RadiationSpectrum,
)

powder_lines = PowderLineCalculator().calculate(
    structure_factors=factors,
    spectrum=RadiationSpectrum.lab_k_alpha("Cu"),
)

corrected = PowderCorrectionCalculator().calculate(
    powder_lines,
    BraggBrentanoGeometry(),
)

for line in corrected.lines_by_angle:
    print(line.two_theta_deg, line.corrected_line_intensity)
```

Packaged laboratory sources are selectable for Cr, Fe, Co, Cu, Mo, and Ag.
Every preset retains Kα1 and Kα2 as separate lines, so their angular separation
remains visible at high angles. A synchrotron wavelength is supplied explicitly:

```python
spectrum = RadiationSpectrum.synchrotron(
    wavelength_angstrom=0.41328,
    source_id="beamline:my-experiment",
)
geometry = BraggBrentanoGeometry(
    perpendicular_polarization_fraction=0.98,
)
```

`intrinsic_line_intensity` contains only normalized radiation weight,
crystallographic multiplicity, Friedel grouping, and `|F|²`. The separate
correction layer returns the Lorentz factor, polarization factor, and
`corrected_line_intensity` for symmetric Bragg–Brentano reflection geometry.
The default polarization fraction is `0.5`, corresponding to unpolarized
laboratory X-rays; synchrotron polarization must be provided explicitly.
These are relative calculated intensities, not an absolute detector signal.

Preferred orientation, absorption, and comparison with experiment are not
part of this line result. `RadiationProbe`
already distinguishes X-rays from neutrons, but neutron powder intensities
will only be enabled together with a separate nuclear scattering-length
context; CrIStMa never substitutes X-ray atomic form factors for neutrons.

## Calculated powder profile

A minimal final forward layer can place intrinsic or corrected powder lines
on an explicit uniform grid. If no instrument calibration is available, the
caller supplies one constant Gaussian FWHM:

```python
from cristma.diffraction import (
    ConstantWidthProfile,
    PowderProfileCalculator,
    UniformTwoThetaGrid,
)

profile = PowderProfileCalculator(max_points=1_000_000).calculate(
    corrected,
    UniformTwoThetaGrid(5.0, 120.0, 0.01),
    ConstantWidthProfile(fwhm_deg=0.10),
)
```

An instrument profile stored by a consuming application can instead provide
explicit GSAS-style continuous-wave `U`, `V`, `W`, `X`, and `Y` values:

```python
from cristma.diffraction import TchProfile

instrument = TchProfile(u=U, v=V, w=W, x=X, y=Y)
profile = PowderProfileCalculator().calculate(
    corrected,
    grid,
    instrument,
    zero_shift_deg=zero_shift,
    d_spacing_scale=estimated_d_scale,
)
```

`d_spacing_scale` is an optional fast peak-position transform for search and
screening workflows. Each radiation component is moved independently using
Bragg's law with `d_scaled = d * d_spacing_scale`; instrument and phase-local
widths are then evaluated at the moved angle, and `zero_shift_deg` is applied
last. The transform deliberately retains the supplied line intensities and
does not claim to recompute the structure, structure factors, multiplicities,
or angle-dependent corrections. Its exact value is recorded in profile
provenance.

CrIStMa has no built-in instrument preset and does not read refinement project
files. Every peak kernel is area-normalized and evaluated only in a local
window. The configurable `max_points` limit is checked before allocating the
output array; an oversized request raises `PowderProfileLimitError` rather than
returning a truncated scientific result.

An optional isotropic sample model adds phase-local coherent-domain size and
microstrain broadening:

```python
from cristma.diffraction import IsotropicSampleBroadening

sample = IsotropicSampleBroadening(
    crystallite_size_nm=80.0,
    microstrain=8.0e-4,
    scherrer_constant=0.9,
)
profile = PowderProfileCalculator().calculate(
    phase_lines,
    grid,
    instrument,
    sample_broadening=sample,
)
```

Each call describes one phase. Size is an isotropic Lorentzian Scherrer
contribution, while microstrain is an isotropic Gaussian
`4 * microstrain * tan(theta)` contribution. They are combined with the
explicit instrument components before the TCH pseudo-Voigt approximation.

The same forward calculation is available through one small facade when the
intermediate results are still required for inspection:

```python
from cristma.diffraction import (
    BraggBrentanoGeometry,
    ConstantWidthProfile,
    IsotropicSampleBroadening,
    PowderPatternCalculator,
    RadiationSpectrum,
    UniformTwoThetaGrid,
)

pattern = PowderPatternCalculator().calculate(
    crystal,
    setting,
    RadiationSpectrum.lab_k_alpha("Cu"),
    UniformTwoThetaGrid(5.0, 90.0, 0.02),
    ConstantWidthProfile(0.10),
    geometry=BraggBrentanoGeometry(),
    sample_broadening=IsotropicSampleBroadening(
        crystallite_size_nm=80.0,
        microstrain=8.0e-4,
    ),
)
```

The facade derives reciprocal coverage from the upper grid boundary and the
shortest selected wavelength, then retains its `ReflectionSet`,
`StructureFactorSet`, intrinsic lines, optional corrected lines, sampled
profile, status, and provenance. Instrument broadening remains mandatory and
explicit; sample broadening belongs only to the phase calculated by that call.
The facade does not read experimental patterns, compare phases, or refine any
parameter.
Every radiation component uses its own wavelength, including K-alpha
doublets. If the consuming application has no instrument calibration, the
same sample model can be combined with `ConstantWidthProfile`; CrIStMa never
invents an instrument setting. Anisotropic size/strain, preferred orientation,
absorption, background, asymmetry, experimental matching, and refinement
remain outside this minimal forward calculation.

## Le Bail intensity extraction and effective profile fitting

The separate inverse-calculation API takes a complete `ReflectionSet`, radiation,
a uniform angular grid, observed counts per point, and an explicit fixed
background. It requires no atom coordinates, calculated F², Finder project or
Rit session. Include reflections covering the measured range and peak tails.

```python
from cristma.diffraction import LeBailExtractor, LeBailProfileRefiner, PseudoVoigtProfile

initial_profile = PseudoVoigtProfile(fwhm_deg=0.10, eta=0.5)
extracted = LeBailExtractor().extract(
    reflections, radiation, grid, observed_counts, background_counts, initial_profile,
)
fitted = LeBailProfileRefiner(
    fwhm_bounds=(0.02, 0.20), eta_bounds=(0.0, 1.0), max_evaluations=256,
).refine(reflections, radiation, grid, observed_counts, background_counts, initial_profile)
print(fitted.status, fitted.profile, fitted.extraction.intensity_groups)
```

This first profile-fitting slice adjusts a single phase's constant effective
FWHM and Lorentzian fraction eta. Cell, angular zero, spectrum and background
remain fixed. Each bounded coordinate-search trial repeats intensity extraction;
only improvements of its unweighted count-residual norm are retained. One may
hold a parameter fixed with `refine_fwhm=False` or `refine_eta=False`.
`fitted.trials`, `diagnostics` and `provenance` retain trial profiles, numerical
termination and search controls. Inner intensity limits and outer evaluation
limits have separate statuses; parameter-bound hits produce diagnostics.
Nonconverged inner trials are rejected and kept in history. The search can
continue with other candidates, but convergence requires a complete valid
final coordinate poll; a failed initial extraction stops it immediately.

The fitted width is an effective phase profile, not an instrument calibration,
size/strain decomposition, or a global least-squares optimum. Search resolution
is not a parameter uncertainty. An atomic model and phase fractions are not
inferred. Coincident families retain summed intensities. Multiphase observations
require a joint model; independently fitting each phase to the whole pattern
does not provide such a model. TCH coefficient refinement is not included yet.

Joint extraction uses explicit phase IDs and one observed pattern:

```python
from cristma.diffraction import (
    LeBailPhase, LeBailMultiPhaseExtractor, LeBailMultiPhaseProfileRefiner,
)

phases = (
    LeBailPhase("main", main_reflections, PseudoVoigtProfile(0.08, 0.5)),
    LeBailPhase("secondary", secondary_reflections, PseudoVoigtProfile(0.10, 0.4)),
)
joint = LeBailMultiPhaseExtractor().extract(
    phases, radiation, grid, observed_counts, background_counts,
)
joint_fit = LeBailMultiPhaseProfileRefiner(
    fwhm_bounds=(0.02, 0.20), max_evaluations=512,
).refine(phases, radiation, grid, observed_counts, background_counts)
```

Each phase has its own fixed cell, reflection set and effective profile.
Intensity redistribution uses the total signal from all phases. Refinement
adjusts independent FWHM/eta pairs against that same total; `fixed_phase_ids`
can retain a phase's profile while its intensities remain jointly extracted.
Search options and inner `extractor=LeBailExtractor(...)` controls match the
one-phase refiner. Returned phases are sorted by phase ID.

`joint.phases[i].calculated` contains that phase's signal **without background**.
The total equals one background plus all phase signals plus
`joint.shared_calculated`. Exactly identical cross-phase kernels have only a
shared intensity; they are excluded from individual phase intensities and
signals. `shared_intensities` retains their phase/reflection references and
summed area. Other overlap allocations remain conditional on the model and
initialization. Le Bail areas are not mass fractions.

The common numerical kernel packs local sampled windows for NumPy operations
up to a bounded sample count and uses the scalar local-window path above that
memory cap. This does not construct a dense grid-by-reflection matrix; the
selected backend is retained in extraction provenance.

For oscillating intensity updates with negative net counts (observations below
the supplied background), an explicit inner setting such as
`LeBailExtractor(relaxation=0.5)` damps the iteration without clipping those
counts or changing the fixed-point equation. Convergence is tested against
the full proposed intensity update before damping. The default remains 1.0;
the chosen factor and count tolerances are retained in provenance. This is
a numerical control, not an automatic correction of the background.

For bounded work, one- and multi-phase profile refiners accept three separate
limits: `extractor.max_iterations` per joint intensity extraction,
`max_evaluations` for trial profiles, and `max_total_iterations` for the sum
of inner iterations across initialization, accepted and rejected trials.
The last trial is capped to the remaining budget, so the total is never
exceeded. A joint iteration covers all phases; it is not counted per phase.

```python
bounded_fit = LeBailMultiPhaseProfileRefiner(
    extractor=LeBailExtractor(max_iterations=1000, relaxation=0.5),
    max_evaluations=20,
    max_total_iterations=5000,
).refine(phases, radiation, grid, observed_counts, background_counts)
print(bounded_fit.status, bounded_fit.total_intensity_iterations)
```

These are example computational budgets, not instrument or scientific presets.
On exhaustion the result retains the best converged trial, or the available
initial extraction if none converged, with explicit `MAX_TOTAL_ITERATIONS`,
`MAX_EVALUATIONS` or inner nonconvergence status. Such a result can be displayed
or used as an approximate starting point, but is not reported as converged.
The iteration budget limits work; elapsed time still depends on pattern size.

Cell and profile refinement is available through `LeBailRefiner`. Supply the
original `UnitCell` for every phase, keyed by its ID, matching that phase's
reflection fingerprint. Select only the added phase, or omit the selection
(`None`) to refine all phases together:

```python
from cristma.diffraction import LeBailRefiner

refiner = LeBailRefiner(
    extractor=LeBailExtractor(max_iterations=1000, relaxation=0.5),
    fwhm_bounds=(0.02, 0.20),
    max_cycles=10, max_evaluations=30, max_total_iterations=5000,
    initial_intensity_iterations=20, intensity_iterations_per_cycle=5,
)
added_only = refiner.refine(
    phases, phase_cells, radiation, grid, observed_counts, background_counts,
    refine_phase_ids=("secondary",),
)
# To refine every phase from the supplied starting values:
all_phases = refiner.refine(
    phases, phase_cells, radiation, grid, observed_counts, background_counts,
    refine_phase_ids=None,
)
fitted_cells = dict(all_phases.cells)
```

Each phase may also supply a `TchProfile(u, v, w, x, y)`. `LeBailRefiner`
then fits independent angular TCH coefficients for that phase, using the same
alternating intensity/cell/profile loop and common iteration budget:

```python
from cristma.diffraction import TchProfile

tch_phases = (
    LeBailPhase("main", main_reflections, TchProfile(2, -2, 40, 4, 3)),
    LeBailPhase("secondary", secondary_reflections, TchProfile(3, -1, 30, 3, 2)),
)
tch_fit = LeBailRefiner(
    tch_refine_parameters=("u", "v", "w", "x", "y"),
    fwhm_bounds=(0.01, 0.6),
    max_cycles=30, max_total_iterations=2000,
).refine(tch_phases, phase_cells, radiation, grid, observed_counts,
         background_counts, refine_phase_ids=None)
```

Use a subset such as `("w", "x", "y")` to hold U/V fixed. Selecting a phase
still fixes every nonselected phase's cell and profile. Constant pseudo-Voigt
and TCH phases can coexist; `refine_fwhm`/`refine_eta` apply to the former,
while `tch_refine_parameters` applies to the latter.

The existing GSAS CW units are preserved: U/V/W describe Gaussian variance in
centidegrees squared; X/Y describe Lorentzian FWHM in centidegrees. This is not
Gaussian FWHM squared in degrees. See the [GSAS-II peak-width definitions](https://github.com/AdvancedPhotonSource/GSAS-II-tutorials/blob/main/MDhelp/docs/powderpeaks.md).
Fitted TCH coefficients are **effective per-phase profiles**; they do not
separately determine instrument calibration, crystallite size or microstrain.

TCH parameter steps are additive and scaled by the initial profile.
`tch_parameter_bound=10.0` bounds those coordinates and
`tch_parameter_tolerance=1e-4` tests their changes. Initial profiles, scales,
active names, bounds, units and `profile_scope="per_phase_effective"` are
retained in refinement provenance. Correlated coefficients may not be unique,
even when the fitted curves agree well; no coefficient uncertainties are
inferred.

Every TCH model must have positive Gaussian variance and nonnegative Lorentzian
width throughout `[0, grid.stop_deg + 25 * maximum_FWHM]`, strictly below 180°.
The validator checks analytic component extrema, including interior extrema,
and conservatively requires their total-FWHM envelope inside `fwhm_bounds`.
That envelope may exclude some otherwise usable profiles; choose suitable
bounds rather than expecting automatic clipping. Lorentzian parameter proposals
are projected onto their feasible linear domain, retaining fixed coefficients;
remaining invalid probes are rejected, with one-sided derivatives when needed.
Published widths are never repaired by clamping.

Selection controls each phase's cell and effective FWHM/eta. Nonselected cells
and profiles remain fixed, while **all phase intensities** are still jointly
extracted from the common pattern. `refine_profiles=False` fits only cells;
`refine_cells=False` fits only selected profiles. This slice retains a fixed
common angular zero, radiation and supplied background.

Cell degrees of freedom follow the exact setting's rotation matrices through
the invariant metric equation `R.T @ G @ R == G`, including nonstandard bases.
Positive-definite metric perturbations are bounded by `metric_strain_bound`.
This is not a box of independent a/b/c/angle changes that could break symmetry.
Trial reflection sets are regenerated for their actual cells and full required
angular/tail coverage; setting IDs, hkl basis and exact absences stay fixed, and
cell fingerprints follow the fitted geometry.

Short intensity blocks alternate with bounded damped Gauss-Newton cell/profile
steps. Intensities are retained by phase and reflection identities between
blocks; an unconverged initial block does not prevent cell refinement.
Parameter trials keep the current areas fixed and require a decreased
unweighted count residual. Rejected trials cannot mutate retained intensities.
A splitting coincident intensity uses a short, budgeted redistribution block,
with an explicit diagnostic rather than an invented partition. This is a
local method and needs sensible starting phase cells; it is not indexing or a
global phase search. Unconstrained directions and stalled/limited calculations
are explicit. `max_cycles` bounds linearizations; `max_evaluations` bounds full
model evaluations (including fixed-area trials); `max_total_iterations` includes every inner iteration,
including rejected trials and coincidence-derivative fallbacks. Jacobian
storage is capped by `max_jacobian_values`. `extractor.max_iterations` also caps
each initialization/refresh block. Profile and parameter stability must persist
for `stable_cycles` complete cycles. `PROFILE_CONVERGED` means this stability
was reached while individual intensities remain unconverged; it does not imply
that overlapping peak areas are uniquely determined. A fixed-area evaluation
has intensity status `NOT_ITERATED`, never a fabricated intensity convergence.

`LeBailRefinementResult` retains initial/fitted cells, initial and best
extractions, trials, actual iteration use, diagnostics and provenance. Trial
`advanced` records working-state steps; `accepted` marks improving best
snapshots. The best snapshot is returned on a limit, with matching cells and
profiles, even if subsequent intensity updates increase the residual. Fitted
cell uncertainties and phase fractions are not inferred. Background and peak
position errors remain separate; [FullProf profile matching documentation](https://www.ill.eu/sites/fullprof/downloads/Docs/FullProf_Manual.pdf)
provides context for the cell/intensity/profile separation.

## Design principles

- **Physics before interface.** Scientific meaning is not determined by a GUI
  or storage format.
- **One canonical model.** Every reader produces the same structure types for
  downstream calculations.
- **Explicit assumptions.** Policies, tolerances, limits, and incomplete
  searches are visible in inputs and results.
- **Traceable results.** Symmetry images, reference data, transformations, and
  diagnostics retain provenance.
- **Composable tools.** Calculators are independent and do not rely on a
  hidden current structure or global workflow.
- **Small runtime.** The core depends only on Python and NumPy.

## Beta status

`0.1.0b1` was the first public beta. `0.1.0b2` added the first diffraction
milestone, explicit crystal-chemistry result statuses, and stable
symmetry-equivalent contact orbits. `0.1.0b3` keeps coordinate structures
available when a reported anisotropic displacement tensor conflicts with site
symmetry, and extends composition grammar to hydrogen-omitted organic and
metal-organic structures. The local beta3 development line also adds
neutral-atom X-ray structure factors with explicit scattering provenance. The
`0.1.0b4` keeps a usable coordinate structure when
an anisotropic ADP fails the final orbit-consistency check: it retains a
reported `U_iso_or_equiv` when available, otherwise omits only that ADP, and
returns a warning instead of rejecting the complete CIF. The published
`0.1.0b5` release introduces orbit-first direct-space crystal chemistry:
validated symmetry contexts, asymmetric-unit pair orbits, chemical contact
orbits, oriented incidences, and multiplicity-weighted coordination-shell
orbits without expanded contacts in the scientific pipeline. The published
`0.1.0b6` unifies reference-cell atom-image identities across
`atomic_view()`, contact materialization, polyhedra, and structural units. It
also accepts symmetry-constrained cells within their componentwise reported
precision, collapses redundant symmetry-expanded CIF atom rows conservatively,
and preserves incomplete polyhedra when hull geometry is unusable. The
local `0.1.0b7` development line adds orbit-first molecular bond and component
analysis with explicit normalized-distance policy and exact periodic-rank
classification. The current `0.1.0b9` development line adds the one-call
powder-pattern facade while retaining every intermediate reciprocal result and
keeping instrument and phase-local sample broadening explicit, plus bounded
molecular rings, pi-system, pi-stacking, and explicit C-H/C-D...pi geometry.
It also assembles these independently calculated interactions into an exact
molecular packing quotient graph. The implemented
scientific core is covered by automated tests and is ready for evaluation and
integration. Until the first stable release, public APIs may still change when
required to correct or clarify scientific contracts.

The current development version adds reciprocal metrics, bounded reflection
generation, exact systematic absences, reciprocal symmetry orbits,
crystallographic multiplicity, Friedel relations, neutral-atom structure
factors, intrinsic multi-component powder lines, selectable X-ray sources, and
Bragg–Brentano Lorentz–polarization corrections, plus minimal calculated
profiles on explicit grids and optional phase-local isotropic
size/microstrain broadening, to the published beta's
structural I/O, symmetry, geometry, crystal chemistry, and topology layers. It
does not calculate anisotropic sample broadening or corrections, neutron
structure factors, experimental matching, or structure refinement.

## Roadmap

Planned scientific layers are developed as independent milestones:

1. energy-dependent and additional scattering contexts;
2. additional powder geometries, sample corrections, and explicit instrument
   models;
3. anisotropic sample broadening and neutron scattering;
4. additional structural transforms, hierarchy and topology tools, and
   refinement built over the same forward calculations.

The roadmap describes direction, not a compatibility or release-date promise.
CrIStMa will remain independent of any particular consuming application.

## License and reference data

Original CrIStMa code is distributed under the permissive
[BSD-3-Clause license](https://github.com/ABKuznetsov/CrIStMa/blob/main/LICENSE).
It may be used in open-source, commercial, and closed-source software subject
to the license notice requirements.

Bundled reference resources retain their own attribution and provenance:

- space-group and Wyckoff data normalized from pinned spglib 2.7.0 resources
  under BSD-3-Clause;
- Cordero covalent radii compiled from QCElemental resources under
  BSD-3-Clause;
- Shannon radii compiled from a pinned pymatgen artifact under MIT;
- neutral-atom X-ray form factors normalized from pinned xraylib 4.3.0 data
  under its BSD-style license, with EPDL97 recorded as the scientific source;
- selected Crystallography Open Database fixtures under CC0/public-domain
  terms;
- curated chemical-reference rules with their scientific literature recorded
  in the versioned resources.

Versions, commits, hashes, known provenance limitations, and redistribution
requirements are listed in
[THIRD_PARTY_NOTICES.md](https://github.com/ABKuznetsov/CrIStMa/blob/main/THIRD_PARTY_NOTICES.md).

## Author

Artem B. Kuznetsov<br>
[GitHub](https://github.com/ABKuznetsov)