Source code for exmecheva.eva

# -*- coding: utf-8 -*-
"""
Functionality for selection of evaluation (single, series or complete) and 
packing of HDF-file.

@author: MarcGebhardt
ToDo:
    - series only work with output_lvl>=1
"""
import os
import traceback
import pandas as pd

import exmecheva.common as emec

[docs]def series(eva_single_func, paths, no_stats_fc, var_suffix, prot_rkws, output_lvl=1, log_scopt={'logfp':None, 'output_lvl': 1, 'logopt':True, 'printopt':False}, plt_scopt={'tight':True, 'show':True, 'save':True, 's_types':["pdf"], 'clear':True, 'close':True}): """ Evaluates a series of single evaluations (one after an other). Parameters ---------- eva_single_func : function Function to perform single evaluation. paths : pandas.Series Paths for evaluation: - 'prot': path to protocoll excel table - 'opts': path to common options as json file - 'meas': path to measurement (conventional) file location - 'dic': path to measurement (optical) file location - 'out': path for output files no_stats_fc : list of strings No evaluation if in protocoll.Failure_code. Example: no_stats_fc = ['A01.1','A01.2','A01.3', 'A02.3', 'B01.1','B01.2','B01.3', 'B02.3', 'C01.1','C01.2','C01.3', 'C02.3', 'D01.1','D01.2','D01.3', 'D02.3', 'F01.1','F01.2','F01.3', 'F02.3'] var_suffix : string Suffix for variant of measurement (p.E. different moistures ["A","B",...]). prot_rkws : dict Dictionary for reading protocol. Must be keyword ind pandas.read_excel. output_lvl : int, optional Output level (0: no output, 1: only necessary, 2: all). The default is 1. Returns ------- None. """ prot = pd.read_excel(paths['prot'], **prot_rkws) logfp = paths['out'] + os.path.basename(paths['prot']).replace('.xlsx','.log') if output_lvl>=1: log_mg=open(logfp,'w') prot.Failure_code = emec.list_ops.list_cell_compiler(prot.Failure_code) eva_b = emec.list_ops.list_interpreter(prot.Failure_code, no_stats_fc) emec.output.str_log("\n paths:",log_mg,output_lvl,printopt=False) for path in paths.index: emec.output.str_log("\n %s: %s"%(path,paths[path]), log_mg,output_lvl,printopt=False) emec.output.str_log("\n evaluation: %d / %d"%(prot.loc[eva_b].count()[0],prot.count()[0]), log_mg,output_lvl,printopt=False) emec.output.str_log("\n%s"%prot.loc[eva_b].Designation.values, log_mg,output_lvl,printopt=False) emec.output.str_log("\n not evaluated: %d / %d"%(prot.loc[eva_b==False].count()[0],prot.count()[0]), log_mg,output_lvl,printopt=False) emec.output.str_log("\n%s"%prot.loc[eva_b==False].Designation.values, log_mg,output_lvl,printopt=False) for eva in prot[eva_b].index: for mfile_add in var_suffix: emec.output.str_log("\n %s"%prot.loc[eva].Designation+mfile_add, log_mg,output_lvl,printopt=False) try: cout = eva_single_func(prot_ser = prot.loc[eva], paths = paths, mfile_add=mfile_add) emec.output.str_log("\n Eva_time: %.5f s (Control: %s)"%(cout[0].iloc[-1]-cout[0].iloc[0],cout[1]), log_mg,output_lvl,printopt=False) except Exception: txt = '\n Exception:' txt+=emec.output.str_indent('\n{}'.format(traceback.format_exc()),5) emec.output.str_log(txt, log_mg,output_lvl,printopt=False) if output_lvl>=1: log_mg.close()
[docs]def selector(eva_single_func, option, combpaths, no_stats_fc, var_suffix=[""], ser='', des='', out_path='', prot_rkws=dict(header=11, skiprows=range(12,13), index_col=0), log_scopt={'logfp':None, 'output_lvl': 1, 'logopt':True, 'printopt':False}, plt_scopt={'tight':True, 'show':True, 'save':True, 's_types':["pdf"], 'clear':True, 'close':True}): """ Selects suitable evaluation method acc. to choosen option. Parameters ---------- eva_single_func : function Function to perform single evaluation. option : str Evaluation option. Possible are: - 'single': Evaluate single measurement - 'series': Evaluate series of measurements (see protocol table) - 'complete': Evaluate series of series - 'pack': Pack all evaluations into single hdf-file (only results and evaluated measurement) - 'pack-all': Pack all evaluations into single hdf-file with (all results, Warning: high memory requirements!) combpaths : pandas.DataFrame Combined paths for in- and output of evaluations. no_stats_fc : list of str Assessment codes for excluding from evaluation (searched in protocol variable "Failure_code"). var_suffix : list of str, optional Suffix of variants of measurements (p.E. different moistures ["A","B",...]). The default is [""]. ser : str, optional Accessor for series. Must be as index in combpaths. The default is ''. des : str, optional Accessor for/Designation of measurement/specimen. Must be as index in combpaths. The default is ''. out_path : str or Path, optional Additional outputpath for packed evaluation (hdf file). The default is ''. prot_rkws : dict, optional Dictionary for reading protocol. Must be keyword ind pandas.read_excel. The default is dict(header=11, skiprows=range(12,13),index_col=0). Raises ------ NotImplementedError Option not implemented. Returns ------- None. """ if option == 'single': mfile_add = var_suffix[0] prot=pd.read_excel(combpaths.loc[ser,'prot'],**prot_rkws) try: _ = eva_single_func(prot_ser=prot[prot.Designation==des].iloc[0], paths=combpaths.loc[ser], mfile_add = mfile_add, log_scopt=log_scopt, plt_scopt=plt_scopt) except Exception: txt = '\n Exception:' txt+=emec.output.str_indent('\n{}'.format(traceback.format_exc()),5) emec.output.str_log(txt, None , output_lvl=1, logopt=False, printopt=True) elif option == 'series': series(eva_single_func=eva_single_func, paths = combpaths.loc[ser], no_stats_fc = no_stats_fc, var_suffix = var_suffix, prot_rkws=prot_rkws, log_scopt=log_scopt, plt_scopt=plt_scopt) elif option == 'complete': for ser in combpaths.index: series(eva_single_func, paths = combpaths.loc[ser], no_stats_fc = no_stats_fc, var_suffix = var_suffix, prot_rkws=prot_rkws, log_scopt=log_scopt, plt_scopt=plt_scopt) elif option == 'pack': emec.loadnsave.comb_logs(in_paths=combpaths, out_path=out_path) packpaths = combpaths[['prot','out']] packpaths.columns=packpaths.columns.str.replace('out','hdf') emec.loadnsave.pack_hdf( in_paths=packpaths, out_path = out_path, hdf_naming = 'Designation', var_suffix = var_suffix, h5_conc = 'Material_Parameters', h5_data = 'Measurement', prot_rkws=prot_rkws, opt_pd_out = False, opt_hdf_save = True ) print("Successfully created %s"%out_path) elif option == 'pack-all': emec.loadnsave.comb_logs(in_paths=combpaths, out_path=out_path) packpaths = combpaths[['prot','out']] packpaths.columns=packpaths.columns.str.replace('out','hdf') emec.loadnsave.pack_hdf_mul( in_paths=packpaths, out_path = out_path, hdf_naming = 'Designation', var_suffix = var_suffix, h5_conc = 'Material_Parameters', prot_rkws=prot_rkws, opt_pd_out = False, opt_hdf_save = True ) print("Successfully created %s"%out_path) else: raise NotImplementedError('Option %s not implemented!'%option)